Product SpecificationsPerformanceRefrigeration Capacity Input Power Efficiency EVAP TEMP COND TEMP AMBIENT TEMP RETURN GAS LIQUID TEMPCondition Test Voltage Btu/ h kcal/ h W W Btu/ Wh kcal/ Wh W/ WEN12900 ASERCOM 100V ~ 50HZ 4191 1056 1228 543 7.72 1.94 2.26 5° C ( 41° F) 45° C ( 113° F) 32° C ( 90° F) 15° C ( 59° F) 45° C ( 113° F)EN12900 ASERCOM 115V ~ 60HZ 4935 1244 1446 670 7.37 1.86 2.16 5° C ( 41° F) 45° C ( 113° F) 32° C ( 90° F) 15° C ( 59° F) 45° C ( 113° F)GeneralEvaporating Temp. Range:-15° C to 15° C ( 5° F to 59° F)Motor Torque:High Start Torque ( HST)Compressor Cooling:FanMechanicalWeight:11.941Weight Unit of Measure:KGDisplacement ( cc) :14.15Oil Type:PolyolesterViscosity ( cSt) :32Oil Charge ( cc) :350ElectricalVoltage Range ( 50 Hz) :90-110Voltage Range ( 60 Hz) :103-127Locked Rotor Amps ( LRA) :33Rated Load Amps ( RLA 50 Hz) :7.5Rated Load Amps ( RLA 60 Hz) :7.2Max. Continuous Current ( MCC in Amps) :10.3Motor Resistance ( Ohm) - Main:1Motor Resistance ( Ohm) - Start:4Motor Type:CSIROverload Type:EXTERNALRelay Type:Current Relay